Integration
and Automation
| |


Replace
RTUs and Integrate
Your Station 

|
SEL-2032 Communications
Processor
- Use plug-in cards in the SEL-2032 to connect IEDs to Ethernet
or Modbus Plus networks.
- Eliminate or reduce the need for SCADA RTUs.
- Simplify, improve the reliability, and reduce the total
cost of SCADA systems by using the SEL-2032 to collect and
scale meter data, and also to collect targets, contact input
status, and fault location directly from relays. Use the
contact outputs of relays and other IEDs for control. Directly
support Modbus RTU Slave and DNP 3.0 Level 2 protocols for
links to RTUs or masters.
- Connect IEDs that do not support Modbus to a Distributed
Control System (DCS). The communications processor provides
faster updates to the DCS than would a multidrop system because
it groups data for more efficient multiple-register or block
access. Arithmetic functions can change scaling, calculate
virtual analog inputs, and compare analog values to thresholds.
Use SELOGIC control equations to combine digital inputs to
initiate and qualify automatic control, or for interlocks.
- Support local HMI on a PC or industrial computer using
the SEL-2032 as a communications hub for gathering data from
and directing control commands to IEDs in the substation.
Local event report collection, settings management, and data
archiving may also be included in the local HMI.
- Set the communications processor to detect critical conditions
and dial a pager. Send an ASCII message to an alphanumeric
pager or an SEL-3010 Event Messenger.
- Use the SEL-2032 as a hub to enable low-cost, point-to-point
fiber-optic links that isolate equipment from hazardous and
damaging ground potential rise; eliminate RFI, EMI, and communications
system ground loops; and allow longer signal paths than possible
with EIA-232 copper connections.
- Acquire and forward information from relays and specialized
equipment monitoring devices to maintenance databases and
expert systems.
- Use SEL-5020 Settings Assistant Software to prepare settings
and communicate with the communications processor.
- Use with SEL-5040 Power System Report Manager Software
to automatically gather relay event reports and manage them
with a database.
|
| |
 |

 |
SEL-2030 Communications Processor with
Card Slot
- Use plug-in cards in the SEL-2030 to connect IEDs to Ethernet
or Modbus Plus networks.
- Use the SEL-2030 as a hub to enable low-cost, point-to-point
fiber-optic links that isolate equipment from hazardous and
damaging ground potential rise; eliminate RFI, EMI, and communications
system ground loops; and allow longer signal paths than possible
with EIA-232 copper connections.
- Support local HMI on a PC using the SEL-2030 as a communication
hub for gathering data from and directing control commands
to IEDs in the substation. Local event report collection, settings
management, and data archiving may also be included in the
local HMI.
- Acquire and forward information from relays and specialized
equipment monitoring devices to maintenance databases and expert
systems.
|
| |
| |
 |
SEL-4388 MIRRORED BITS® Tester
- Use the new handheld SEL-4388 MIRRORED BITS Tester to quickly test serial communications channels and SEL MIRRORED BITS communications. The SEL-4388 gives engineers and technicians the power to accelerate commissioning and bench testing, and to improve cable identification, training, and maintenance.
- Connect directly to EIA-232 MIRRORED BITS communications channels, or use the included EIA-232 extension cable
- Connect to remote devices through fiber-optic MIRRORED BITS channels
- Read sensed parameters from LCD display
- Transmit MIRRORED BITS using pushbuttons
- Observe LED status of eight bits sent in each direction
- Power from an optional 230-0601 AC Power Adapter or a station-battery-powered SEL-9321 Low-Voltage DC Power Supply for bench testing or other applications where you don't need the portability provided by batteries.
Learn More About the SEL-4388
|
 |
 |
SEL-2701 Ethernet Processor Card
- Use the SEL-2701 Ethernet Processor Card to provide Ethernet
and UCA2 interconnectivity through the SEL-2030 Communications
Processor to relays and IEDs.
- MMS/UCA2 interconnectivity through the SEL-2030 Communications
Processor for the existing SEL product line.
- Lowest cost UCA2 interconnection for multiple IEDs plus the
reliability and data concentration advantages of the communications
processor.
- Uniform implementation and models residing in SEL-2701 Ethernet
Processor lead to efficient use of training tools, spares, and
settings across SEL product lines.
|
| |
| |
 |
SEL-2711
Modbus Plus Protocol Card
- Open your Modbus
Plus* network to the field-proven technology and advanced data
gathering capabilities of the SEL-2032 or SEL-2030 Communications
Processors. The SEL-2711 Modbus Plus Protocol card offers the
key to connectivity with integrated systems using Modbus Plus.
You can now combine the powerful communication and integration
features of the SEL-2032 / SEL-2030 with the vast array of Schneider Automation
products for substation automation. The SEL-2711 dual rear-port
design allows for dual-cable Modbus Plus communication interface.
In addition, the flexible multiple-slot design of the SEL-2030
allows installation of two cards. With two cards, you can implement
redundant dual-cable Modbus Plus interfaces or combine card-specific
protocol interfaces.
*Modbus Plus used under license from Schneider Automation.
|
| |
| |
 |
SEL-3301
Protocol Gateway
- Connect
to SEL communications processors in a substation to convert
relay data from DNP3 protocol to a legacy protocol for a
SCADA master. Use data from SEL relays and other devices
instead of lower reliability remote terminal units.
- Connect
to an RTU to communicate with multiple SCADA masters and
local systems using different protocols
|
| |
| |


Click for larger view
|
SEL-3351
System Computing Platform
- Connect a video monitor, keyboard, and mouse to provide a
human-machine interface (HMI) for alarm annunciation, local
indication, control, and configuration.
- Connect to SEL communications processors in a substation
to convert relay data from DNP3 protocol to a legacy protocol
for a SCADA master. Use data from SEL relays and other devices
instead of lower reliability remote terminal units.
- Connect to an RTU to communicate with multiple SCADA masters
and local systems using different protocols. Optional protocols
include DNP3 Master, DNP Slave, DNP3 LAN/WAN Master, DNP3 LAN/WAN
Slave, Harris 5000 Slave, SEL Fast Messages Master, OPC Client,
and OPC Server. Coming soon are IEC-60870-5-101 Master and
Slave, IEC-60870-5-104 Master and Slave, IEC-60870-5-103 Master,
and IEC61850. For protocols not listed, click here to see the
other protocols in the library.
- Use the SEL-5040 Power System Report Manager to detect, gather,
and summarize relay event reports.
- Gather time-tagged events from SEL relays and I/O Processors
to serve as a station-wide Sequential Event Recorder (SER).
Forward data to a system-level computer for system-wide SER.
- Perform automatic control using SELOGIC control equations
in SEL relays, communications processors, and controllers,
and software logic in the SEL-3351.
- Concentrate data from relays, communications and logic processors,
and other devices; forward information to multiple master data
users, for example, SCADA, EMS, Power Quality, and Equipment
Maintenance systems.
- Install a complete SEL-7000 Integrated Substation System
for control, automation, monitoring, and protection, that includes
an SEL-3351 System Computing Platform. Implement the appropriate
applications to meet your requirements.
- Work with the SEL Systems and Services Division to develop a custom solution for your application.
|
| |
| |
 |
SEL-2410
I/O Processor
- Use in a system with SEL communications
processors, relays, and other devices, instead of an RTU.
An RTU provides only remote I/O for SCADA; therefore, you
do not benefit from the other functions available through
an SEL communications processor-based system—protection
settings management, power system report management, high-speed
local logic, direct engineering access, and more.
- Use SEL communications processors,
relays, remote I/O modules, and I/O controllers for higher
reliability, lower cost, and more functions, instead of settling
for an RTU.
- Sense up to eight pressures, temperatures,
fluid levels, or other process values with an analog input
card. Report these values to SCADA or DCS systems, and use
them in local automatic control equations.
|
| |
|
SEL-2411
I/O Processor
Add I/O to substation SCADA systems and plant control systems, and implement stand-alone monitoring and control using the SEL-2411 Programmable Automation Controller. The base unit includes three digital outputs, two digital inputs, and four plug-in card slots. Optional SELECT™ I/O cards include:
- Eight analog inputs (AI) for dc process values
- Eight digital inputs (DI) to sense status of contacts
- Eight digital outputs (DO) to control external devices
- Four DI and Four DO
- Four AI and Four Analog Outputs (AO)
- Three ac voltage inputs
- Four ac current inputs
- Three ac current and three ac voltage inputs
- 10 RTD inputs
Analog inputs are field-selectable for voltage or current signals. Digital inputs are time-tagged to the nearest millisecond for inclusion in Sequential Events Recording (SER) reports. Implement local control using I/O and SELOGIC® control equations, including logic, arithmetic, timer, and edge-trigger functions.
Choose from Ethernet, EIA-232, EIA-485, Modbus® Serial, DNP3 Serial, Modbus TCP, DNP3 LAN/WAN, IEC 61850, SEL MIRRORED BITS® communications, Telnet, and File Transfer Protocols. Pick one or multiple connections, including Modbus and DNP sessions.
|
| |
|
 |

Demo an SEL-2890 connected
to an SEL-387A |
SEL-2890 Ethernet Transceiver
- Use SEL-2890 Transceivers and your Ethernet network instead
of expensive leased or dial-up connections to reduce monthly
operating costs. Connect to a serial port on your PC to operate
proprietary device-support software through an Ethernet network
without modifying the PC software. Replace a multidrop wired
network (e.g., serial Modbus®).
- Communicate with sites that have valuable data where leased
or dial-up lines were too costly.
- Use Telnet software for ASCII terminal connections to check
the status, read metering data, or to examine history
of event records.
- Use familiar Web browser interfaces to easily view information
with minimal training. The SEL-2890 Transceiver provides
a Web page. Customize the Web page using your browser
FTP features.
- Set the transceiver to send email when power system faults
occur, including the fault type and location. Send
SEL relay automatic
messages to specified addresses for quick notification
and logging.
- Use SEL-5010 Relay Assistant Software with Ethernet Option
to manage the settings for relays connected to
the host SEL-2032/2030. Email automatic messages from the relay.
- Use SEL-5040 Power System Report Manager Software to
automatically gather relay event reports on your
PC and manage them with
a database.
|
| |
| |
 |
SEL-2020
Communications Processor
- Simplify, improve the reliability, and reduce the total cost
of SCADA systems by using the SEL-2020 to collect and scale
meter data, and also collect targets, contact input status,
and fault location directly from relays. Use the contact outputs
of relays and other IEDs for control. Directly support Modbus
RTU Slave and DNP 3.00 protocols for links to RTUs or masters.
- Connect IEDs that do not support Modbus to a Distributed
Control System (DCS). The communications processor provides
faster updates to the DCS than would a multidrop system because
it groups data for more efficient multiple-register or block
access. Arithmetic functions can change scaling, calculate
virtual analog inputs, and compare analog values to thresholds.
Use SELOGIC Control Equations to combine digital inputs to
initiate and qualify automatic control, or for interlocks.
- Support local HMI on a PC or industrial computer using the
SEL-2020 as a communications hub for gathering data from and
directing control commands to IEDs in the substation. Local
event report collection, settings management, and data archiving
may also be included in the local HMI.
- Set the communications processor to detect critical conditions
and dial a pager. Send an ASCII message to an alphanumeric
pager.
- Use the SEL-2020 as a hub to enable low-cost , point-to-point
fiber-optic links that isolate equipment from hazardous and
damaging ground potential rise; eliminate RFI, EMI, and communications
system ground loops; and allow longer signal paths than possible
with EIA-232 copper connections.
- Acquire and forward information from relays and specialized
equipment monitoring devices to maintenance databases and expert
systems.
- Use SEL-5020 Settings Assistant Software to prepare settings
and communicate with the communications processor.
- Use with SEL-5040 Power System Report Manager Software to
automatically gather relay event reports and manage them with
a database.
- Use SEL-5010 Relay Assistant Software to manage your relay
settings.
|
| |
|
|
|