Line Protection

 

 

CE image

SEL-421 High-Speed Line Protection, Automation, and Control System

  • Apply complete pilot protection for primary and backup, and single- or three-pole tripping schemes on transmission and subtransmission lines.
  • Make settings for up to four shots of automatic breaker reclosing for one or two circuit breakers, with synchronism and voltage checks to optimize system restoration.
  • Use the built-in fault locator to efficiently dispatch line inspection and repair personnel.
  • Implement breaker failure logic for one or two circuit breakers.
  • Schedule as-needed circuit breaker maintenance and send alarms when the breaker monitor detects excess breaker contact wear from the number of operations and magnitude of interrupted current.
  • Alarm for low-voltage conditions on one or two station batteries.
  • Track average and last circuit breaker operate time. Alarm on slow circuit breaker.
 
 

SEL-311L
CE image

SEL-311L Line Current Differential Protection and Automation System

  • Apply a complete multiprinciple protection scheme in one relay. In addition to a superior differential function, a complete distance and directional overcurrent relay is included in the standard product.
  • The Alpha plane restraint principle, used in the SEL-311L Relay, is more secure, provides better sensitivity, and is easier to set than percent restraint, dual slope restraint, charge comparison, or phase comparison relays offered by our competition.
  • Applying the differential protection of the SEL-311L can be done for the large majority of applications (overhead lines and cables, all voltage classes) by simply selecting the CT ratio for all terminals and configuring the communications channels. No fault studies are required.

 

 


CE image

SEL-311 Phase and Ground Distance Relay

  • Economical phase and ground distance protection for utility intertie connections.
  • Backup transformer and generator protection with zone distance and overcurrent elements.
  • Built-in fault locator for efficient use of line inspection and repair personnel.
  • SELOGIC® control equations for customizing advanced protection and control schemes.
 

CE image

SEL-321 Phase and Ground Distance Relay

  • Select the SEL-321 Relay for complete distance protection including single-pole tripping and series-compensated lines.
  • Apply the SEL-321 Relay for primary and/or backup single- or three-pole trip transmission line protection, including series-compensated lines.
  • Use the advanced single-pole tripping logic with phase selection, open-pole interval protection, and phase discordance logic with three-pole trip to protect against excessive single-pole open events.
  • Select the load-encroachment feature to prevent operation of three-phase elements under high load conditions.
 


Selecting certain optional features for this product may affect CE conformity - please consult your customer service representative for details.

SEL-351 Directional Overcurrent and Reclosing Relay

  • Protect and control radial or looped transmission, subtransmission, or distribution circuits.
  • Use pilot protection on transmission or subtransmission circuits, including three-terminal lines.
  • Apply directional and nondirectional overcurrent protection for transformer/bus main/bus-tie breaker.
  • Protect small generators and distributed generation interconnections.
   
 
   